{"product_id":"superflo-vst-variable-speed-pump","title":"Pentair SuperFlo VST 1.5 HP Variable Speed Pool Pump | EC-342002","description":"\u003ch2\u003eKey Benefits + Equipment Upgrade Benefits\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVariable-speed operation supports more efficient circulation than running a conventional single-speed pump at full speed.\u003c\/li\u003e\n\u003cli\u003eDual-voltage 115–230V input provides flexibility for common replacement installations.\u003c\/li\u003e\n\u003cli\u003eThree programmable speeds, an override setting, and a real-time 24-hour clock simplify daily scheduling.\u003c\/li\u003e\n\u003cli\u003eRS-485 connectivity supports integration with compatible automation systems and connected devices.\u003c\/li\u003e\n\u003cli\u003eTEFC motor construction and an improved mechanical seal support dependable, quieter operation.\u003c\/li\u003e\n\u003cli\u003eDesigned as a drop-in replacement for existing Pentair SuperFlo pumps and Hayward Super Pump applications; verify fit and system requirements before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eQuick Product Summary\u003c\/h2\u003e\n\u003cp\u003eThe Pentair SuperFlo VST EC-342002 is a 2.2 THP variable-speed pool pump built for everyday circulation, equipment upgrades, and common SuperFlo or Hayward Super Pump replacement applications. Its dual-voltage input, programmable controls, TEFC motor, and RS-485 connectivity give pool owners greater scheduling flexibility while helping qualified installers simplify compatible replacement projects.\u003c\/p\u003e\n\u003ch2\u003eBest For\u003c\/h2\u003e\n\u003cp\u003ePool owners replacing an existing Pentair SuperFlo pump or a compatible Hayward Super Pump installation, upgrading from single-speed operation, or adding programmable circulation control to an in-ground pool system.\u003c\/p\u003e\n\u003ch2\u003eWhy This Matters\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLets circulation speed match filtration, cleaning, and other operating needs instead of running at one fixed speed.\u003c\/li\u003e\n\u003cli\u003eProvides onboard scheduling for routine operation without relying solely on an external time clock.\u003c\/li\u003e\n\u003cli\u003eOffers dual-voltage flexibility for qualifying replacement projects.\u003c\/li\u003e\n\u003cli\u003eSupports automation communication through an RS-485 connection.\u003c\/li\u003e\n\u003cli\u003eHelps buyers identify the correct SuperFlo VST model by matching item 342002 and SKU EC-342002.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCommon Signs You Need This \/ Use This When\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYour existing single-speed pump runs at full speed for every circulation task.\u003c\/li\u003e\n\u003cli\u003eYour current Pentair SuperFlo or Hayward Super Pump installation is being evaluated for replacement.\u003c\/li\u003e\n\u003cli\u003eYou want programmable pump speeds and a built-in 24-hour operating schedule.\u003c\/li\u003e\n\u003cli\u003eYour pool system needs a variable-speed pump that can operate on a verified 115V or 230V supply.\u003c\/li\u003e\n\u003cli\u003eYou need RS-485 communication for a compatible automation installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eProduct Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003ePentair\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSuperFlo VST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable-Speed Pool Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e342002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eEC-342002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication\u003c\/td\u003e\n\u003ctd\u003eIn-ground pool circulation and replacement pumping\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Replacement Use\u003c\/td\u003e\n\u003ctd\u003eExisting Pentair SuperFlo pumps and Hayward Super Pump applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115–230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency \/ Phase\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz, single phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Horsepower\u003c\/td\u003e\n\u003ctd\u003e2.2 THP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeighted Energy Factor\u003c\/td\u003e\n\u003ctd\u003e7.3 at 115V; 9.0 at 230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService Factor\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic Horsepower\u003c\/td\u003e\n\u003ctd\u003e1.08 HHP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControls\u003c\/td\u003e\n\u003ctd\u003eDigital keypad with three programmable speeds, override, and 24-hour clock\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eRS-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor\u003c\/td\u003e\n\u003ctd\u003eTotally Enclosed Fan Cooled (TEFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e28.38 x 12.63 x 15.63 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e53 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eENERGY STAR certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eCompatibility \/ Fitment Notes\u003c\/h2\u003e\n\u003cp\u003ePentair identifies the SuperFlo VST as a drop-in replacement for existing Pentair SuperFlo pumps and Hayward Super Pump applications. Confirm the current pump model, plumbing position, available electrical supply, required flow, total dynamic head, and automation interface before purchase. A similar footprint does not replace proper hydraulic sizing.\u003c\/p\u003e\n\u003ch2\u003eInstallation \/ Use Notes\u003c\/h2\u003e\n\u003cp\u003eHave a qualified pool professional confirm the pump is properly sized for the pool’s hydraulic requirements and verify the existing plumbing footprint, voltage, bonding, and automation compatibility. Install and wire the pump according to the Pentair SuperFlo VST manual and applicable codes. After installation, program the three operating speeds and schedules for the pool’s circulation needs. Do not service the pump while it is energized or while the system is pressurized.\u003c\/p\u003e\n\u003ch2\u003eBuy with Confidence\u003c\/h2\u003e\n\u003cp\u003eBenchmark Pool Supply combines professional pool-equipment knowledge with clear model and SKU identification to help customers choose equipment confidently. Before ordering EC-342002, verify pump sizing, plumbing fit, voltage, and automation requirements so the selected pump matches the pool system.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003ch3\u003eWhat is the Pentair EC-342002 SuperFlo VST pump?\u003c\/h3\u003e\u003cp\u003eIt is a variable-speed pool circulation pump in Pentair’s SuperFlo VST line. Pentair lists item 342002 at 2.2 total horsepower with dual-voltage capability, programmable speeds, and RS-485 connectivity.\u003c\/p\u003e\n\u003ch3\u003eCan EC-342002 replace a Pentair SuperFlo or Hayward Super Pump?\u003c\/h3\u003e\u003cp\u003ePentair describes the SuperFlo VST as a drop-in replacement for existing Pentair SuperFlo pumps and the Hayward Super Pump. Confirm the plumbing footprint, electrical supply, and required hydraulic performance before ordering.\u003c\/p\u003e\n\u003ch3\u003eDoes the SuperFlo VST EC-342002 operate on 115V and 230V?\u003c\/h3\u003e\u003cp\u003eYes. Pentair states that the pump adapts to 115–230V and 50\/60 Hz single-phase power without manual voltage switching. Installation should follow the Pentair manual and applicable electrical codes.\u003c\/p\u003e\n\u003ch3\u003eHow much horsepower does Pentair list for model 342002?\u003c\/h3\u003e\u003cp\u003ePentair lists model 342002 at 2.2 THP and describes it for new installations or replacement applications where a pump up to 1.5 HP is required. Proper sizing should be based on the pool’s hydraulic requirements.\u003c\/p\u003e\n\u003ch3\u003eIs professional installation recommended for EC-342002?\u003c\/h3\u003e\u003cp\u003eYes. A qualified pool professional should verify pump sizing, plumbing fit, voltage, bonding, and automation connections, then install and program the pump according to Pentair’s instructions.\u003c\/p\u003e","brand":"Pentair","offers":[{"title":"Default Title","offer_id":43539592872010,"sku":"EC-342002","price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0637\/6580\/7178\/files\/superflo-vst-pool-pump.png.thumb.1280.1280.png?v=1788372843","url":"https:\/\/benchmarkpoolsupply.com\/products\/superflo-vst-variable-speed-pump","provider":"Benchmark Pool Supply","version":"1.0","type":"link"}